ANTIBACTERIAL・STATIC ELIMINATOR
FUNCTION

About Antibacterial・Static Eliminator Function

LAMETEX

LAMETEX

Copper alloy antibacterial slit yarn

  • ・Excellent antibacterial effect demonstrates effectiveness even in the absolute dry state
  • ・Neutralizes the static electricity
  • ・Metallic luster that takes into consideration ease of design suppressing the color of copper

Features

Introduction to the main features of copper alloy antibacterial slit yarn.

  • 優れた抗菌防臭効果

    Excellent antibacterial effect
  • 静電気をカット

    Cuts static electricity
  • ラメ光沢で意匠性を付与

    Ease of design with glossy lame

Safety and security test results

  • ① Mutagenicity test: Negative
  • ② Skin irritancy test: Negative
  • ③ Skin sensitization test: Negative
  • ④ Skin patch test: Negative

All negative. Can be used with confidence as the product is safe.

フラスコイメージ

Test inspection report

This is to certify that the test results of the test specimen requested to be tested on August 5, 2016 is as given below.

Kyoto Institute of Microbiology
Review manager: Sano Junko

1 .  Test specimen name: Copper alloy film Silver and Gold
2 . Test purpose: Sterilization activity evaluation test
3 . Test method: JIS L 1902
0.4 g of the test specimen is sterilized in an autoclave in accordance to “JIS L1902:2002 Bacterial liquid absorption method”. Next, 0.2 ml of the bacteria solution is inoculated into the test specimen after preparation with 1/20 nutrient medium such that 105 CFU/ml is obtained, and the number of bacteria is measured. Standard fabric is used as the control.
4 . Strain used: Staphylococcus aureus     NBRC-12732
5 . Culture medium used: Nutrient Broth (DIFCO)
Nutrient Agar (DIFCO)

6 . Test results

Antibacterial lame yarn used
Bacteria name Change in the number of bacteria over time
Initial 18hrs-1 18hrs-2 18hrs-3 Average
St.aureus 1.3×10 5 <100 <100 <100 <100
Antibacterial lame yarn not used
Bacteria name Change in the number of bacteria over time
Initial 18hrs-1 18hrs-2 18hrs-3 Average
St.aureus 1.3×10 5 2.4×10 7 2.6×10 7 1.7×10 7 2.2×10 7

※  <100 : Did not detect      Unit:  CFU/mL

テーブルsp用

  

static electricity elimination test certificate

                                               
Item name: A alloy antibacterial lame 1/4 course use    B alloy antibacterial lame 1/2 course use
C pure silver lame 1/4 course use              D sterling silver lame 1/2 course use        4 points
Test item: half life other
The test results of samples submitted to our office on january 29, 2013 will be proved as follows.
February 5, heisei 20 Kaken Test Center General
Kyoto Laboratory
(Japan science fiber inspection association)   

1 . Test results

                                                                                                  
Test item Trial      Conclusion    Fruit Test method
① a ② b ③ c ④ d
Half life (sec) 3.7 4.6 8.5 10 jis l 1094-2008
Half- temperature and humidity of the test room: 20 °c, 40% rh
Laundry treatment: untreated
Friction zone voltage
(v)
Cotton Height 1100 720 820 540 Jis l 1094-2008
Friction band voltage measurement method
Friction cloth: cotton and wool
Temperature and humidity of the test room: 20 °c, 40% rh
Laundry treatment: untreated
Width 830 600 560 370
Wool Heigh 960 480 630 490
Width 930 600 600 500
    

for table sp

  

TEL. 0774-76-2744

Contact us via E-mail

Click for inquiry / request for materials

Please feel free to contact us over the telephone or via E-mail with your inquiries and brochure requests.